AirClean® Systems Endocavity Vaginal Probe Holder Workstations protect the user from Glutaraldehyde, O.P.A., Cidex®, Hydrogen Peroxide and Peracetic Acid while providing a convenient method to handle intracavity probes during disinfection procedures. Ultrasound Workstations may be bench-top or wall-mounted for convenient access. |
| |
|
|
| |
Features:
- SoftClips™ on the front of the ultrasound workstation hold probes in position for disinfection without damaging sensitive electronics or cables.
- All structural polypropylene — “No More Rust” — eliminates corrosion and potential difficult to clean rust spots common to metal ultrasound soaking stations.
- No sharp metal edges — all plastic construction helps prevent scuffing your probes on sheet metal edges.
- Chemisorptive bonded carbon neutralizing filter. This high capacity “No Dust” filter eliminates fumes for twelve months — guaranteed!
- Removable clear front panel for ease of access to bottles.
Eliminate Exposure to:
• Glutaraldehyde
• O.P.A. (ortho-Phthaladehyde)
• Cidex®
• Hydrogen Peroxide
• Peracetic Acid
Fact: All chemical high-level disinfectants are by nature harmful to humans. Reduce or eliminate your exposure to vapors at their source.
|
 |
|
Vaginal / Rectal Probe Holder Protects Probes
Let AirClean® Systems SoftClip™, not luck, hold your probe in place during disinfection. Using correctly sized disinfection containers, you can avoid spills and damaged scopes during the cleaning process.
Fume Containment Experience
AirClean® Systems invented the benchtop glutaraldehyde containment system now used in medical institutions throughout the world. |
|
| |
|
| |
The ACVP50 ultrasound soaking station can be used on a countertop or mounted to a wall for use within the medical facility. |
SPECIFICATIONS |
ACVP50 Series |
OUTSIDE DIMENSIONS |
16"W x 12"D x 16"H |
AIRFLOW |
100LFM at face |
HEIGHT OF BOTTLES/TUBES |
8 inches |
N0. OF CONTAINERS OR TUBES |
3 standard |
FILTER |
12 months guaranteed |
ELECTRICAL |
110V 60W |
CONSTRUCTION |
Structural polypropylene |
VOLUME OF FILTERED AIR |
150 CFM max |
WEIGHT |
28 lbs. with filter |
MOUNTING |
Wall or bench-top |
FILTER TYPE |
Glutaraldehyde |
ACFVPGLT |
Ortho-Phtalaldehyde |
ACFVPOPA |
Peracetic Acid, Hydrogen Peroxide |
ACFVP100 |
|
|
|
| |
 |
ACVP50 Series
The ACVP 50 Series is available with three containers. One container is used primarily for rinsing of the probe after disinfection. When not in use, the container lid should be secured and the unit switched off.
FACT:
- Meets OSHA and JCAHO regulatory requirements.
- Meets UL, CSA and CE requirements.
- Complies with ANSI/AAMI ST58 for safe use and handling of glutaraldehyde-based products in health care facilities.
- Each ultrasound vaginal probe holder workstation’s bonded carbon filter is guaranteed for twelve months.
|

SoftClip™ vaginal / rectal probe holder holds probes in position for disinfection without damaging sensitive electronics or cables. |

The ACVP50 bonded carbon filter has a solid 8 pound mass to effectively adsorb and neutralize high level disinfectant fumes and vapors. AirClean® Systems guarantees this filter for 12 months. |
|
| |
The following information is necessary to determine proper soaking conditions for your probe.
1. How far will you be immersing your probe? (Refer to diagram above)
2. Number of probes to be soaked at the same time (one container is used for rinse)
3. What is the length of your probe? (Refer to #3 on diagram)
4. Is probe flexible or rigid?
Saves you money!
Generally uses less disinfectant than other methods and helps prevent damage to costly probes.
- Meets OSHA and JCAHO regulatory requirements.
- Meets UL, CSA and CE requirements.
- Complies with ANSI/AAMI ST58 for safe use and handling of glutaraldehyde-based products in
health care facilities.
*The use of other companies registered trade names are provided for informational purposes only. Endorsement of these companies' products by AirClean Systems or their endorsement of AirClean Systems is neither given or implied.
|